PFT-503CMF

The PFT503CMF 0-50kV Hipot tester is a compact, portable high-performance solution designed to test the dielectric strength of electrical insulation. Crafted for both field and laboratory applications, this device delivers precise voltage control up to 50kV and features in-built metering for accurate readings. Safety is a priority, with zero start interlock, overload protection, and emergency off functionality. This advanced testing equipment ensures that high-voltage electrical systems meet rigorous safety and performance standards, making it indispensable for electrical maintenance and compliance endeavours.

Specifications
  • Standard Accessories:Transport case, mains cable, HV output cable, earth cable and operating manual
  • Power Supply:230 VAC, 50/60 Hz
  • Output Voltage:0–50 kV AC
  • Rated Output:1 kVA resistive load; 3 kVA capacitive load; up to 60 mA, with output current reduced at lower voltages
  • Voltmeter:Scaled 0–25/0–50 kV AC, ±2% F.S.
  • Ammeter:Scaled 0–1 mA, ±2% F.S., with range multipliers of ×1, ×10 and ×100
  • Duty Cycle:3 kVA: ½ hour ON, 2 hours OFF; 2 kVA: 1 hour ON, 1 hour OFF; 1 kVA: continuous
  • Dimensions:534 mm L × 286 mm W × 387 mm H
  • Weight:34 kg
Applications
  • Switchgear testing: The 0-50kV Hipot tester ensures switchgear operates safely under high voltage, preventing costly downtime. It’s a proactive tool for maintaining electrical infrastructure, offering thorough insulation checks vital for system integrity and operational safety in various industries.
  • Circuit breaker certification: This equipment is integral for certifying circuit breaker insulation, a non-negotiable for electrical system safety. It helps identify potential failure points, ensuring circuit breakers act reliably under fault conditions.
  • Recloser equipment checks: The reliable operation of reclosers is crucial for network resilience. The 0-50kV Hipot tester’s adjustable output is key for testing these components, ensuring they can withstand voltage fluctuations and maintain power system stability.
  • Motor and generator winding assessment: This high-potential tester can evaluate the insulation of motor and generator windings to prevent failure. It’s essential for predictive maintenance strategies that extend the lifespan of these critical components and ensure uninterrupted industrial operations.
  • Insulation testing for iso phase busbars: Iso phase busbars are critical in power transmission, and the 0-50kV Hipot tester can guarantee their insulation is robust enough to prevent breakdowns. This test is non-negotiable in power generation and distribution, where failure can result in widespread outages and significant financial losses.
  • Vacuum bottle verification: The 0-50kV Hipot tester can confirm the integrity of vacuum bottles used in switchgear. It ensures these components can reliably insulate and interrupt high-voltage circuits.
  • Rubber glove testing: This hipot tester is crucial for certifying the insulating efficacy of rubber gloves, which are essential for the safety of electrical workers. Simulating operational electrical stresses ensures that gloves meet stringent safety standards.
Key features
  • Continuously adjustable output voltage
  • Fixed overload, factory set to 120% of rated output current
  • Zero start and external interlock provision
  • Secondary connected dual-range voltmeter
  • Only single piece, shielded cable output AC hipot rated 50 kVac @ 3 kVA. Half the size and weight of others and easier to use.
  • Three-range current meter with isolated guard/ground return circuit
  • Capacitive load compensation
  • Shielded output cable
  • One-piece portable design
  • Automatic transit protected meters
  • Rugged case with cushion grips
  • Simple controls
Benefits
  • Ensures compliance with stringent safety standards.
  • Identifies potential insulation failures to prevent downtime.
  • Reduces operational risks through advanced safety features.
  • Portable and user-friendly design simplifies testing processes.
  • Reliable performance for a wide range of high-voltage applications.
Same category

Other cable & partial discharge testing options

b2 Electronics PDTD 68 Partial Discharge Diagnostics System
Cable & Partial Discharge Testingfrom$780/day
b2 Electronics

PDTD 68

The PDTD68 Partial Discharge Diagnostics System, when paired with the b2 HVA60, enables unmatched insights into insulation degradation…

Read more
Omicron MPD 800 / RBP1 Partial Discharge Measurement System
Cable & Partial Discharge Testingfrom$695/day
Omicron

MPD 800 / RBP1

Our OMICRON MPD 800 universal partial discharge (PD) measurement and analysis system represents the next generation of our widely used and…

Read more
b2 Electronics HVA 68-2 VLF High Voltage Test Set
Cable & Partial Discharge Testingfrom$620/day
b2 Electronics

HVA 68-2

The HVA68-2 is a member of the HVA series with extra power, with an output current up to 88 mA. This extends greatly the maximum load and…

Read more
Back to the catalogue