Omicron

MCC 210

The Omicron MCC 210 is a partial discharge coupling unit, designed to enhance the sensitivity and accuracy of PD measurements and voltage signals in high-voltage equipment. With a high coupling capacity of 1nF or more, it ensures exceptional sensitivity in low-frequency ranges, adhering to IEC 60270 standards. Its capability to remain PD-free up to its maximum test voltage makes it a reliable choice for testing individual devices and applications in small high-voltage labs up to 100 kV. Weighing just 11kg, it’s both portable and practical, operating seamlessly with the MPD600 system for precise diagnostics.

Specifications
  • MCC 210
  • Cable & Partial Discharge Testing
  • Calibrated rental equipment
Applications
  • Factory acceptance testing: For medium voltage and high voltage cables, including conductors, sheaths and shields. The MCC 210 ensures that your product is of the highest quality and free of manufacturing defects that will limit its lifespan and cause costly recalls.
  • Commissioning and site acceptance testing: For medium voltage and high voltage cables, including conductors, terminations, joints, sheaths and shields. 23% of all MV and HV cable failures are caused by termination and jointing faults, which can be detected using the MCC210, MPD 600, and a PD-free source, such as the Phenix BK130/36.
  • Maintenance testing – For medium voltage and high voltage cables, including conductors, terminations, joints, sheaths and shields. 57% of all MV and HV cable failures are caused by cable insulation failures, which can be detected before they fail with the use of the MCC210, MPD 600 and a PD-free source such as the Phenix BK130/36. This saves unnecessary damage and costly downtime.
  • Factory acceptance testing: For medium voltage and high voltage electrical components, including voltage transformers, current transformers, bushings, insulators, windings and capacitors. The MCC 210 ensures that your product is of the highest quality and free of manufacturing defects that will limit its lifespan and cause costly recalls.
  • Commissioning and site acceptance testing – For medium voltage and high voltage electrical components, including voltage transformers, current transformers, bushings, insulators, windings and capacitors. The FAT may be fine, but damage in freight or poor workmanship in installation can cause partial discharge faults in this equipment, which is insidious and hard to find, taking years to present, and typically in catastrophic failure. Still, it can be detected with the use of the MCC210, MPD 600 and a PD free source such as the Phenix BK130/36. For partial discharge equipment, the Omicron MPD 600, Phernix BK130/36 (PD free), b2 PDTD60-2, Ultra TEV Plus 2 and Phenix 50kV PD Free HiPot also stand out for their ability to detect and analyse partial discharges accurately, ensuring the reliability and safety of electrical installations.
Key features
  • Decouples PD measurements and voltage signals from the high-voltage potential.
  • High coupling capacity (1nF or higher) for excellent performance in low- frequency ranges.
  • PD-free operation up to its maximum PD test voltage.
  • Lightweight and portable design for ease of transport and handling.
  • Fully compatible with the Omicron MPD 600 system for advanced testing.
Benefits
  • Exceptional Sensitivity: High coupling capacity (1nF or more) ensures accurate PD measurements even at low frequencies.
  • Reliable and Compliant: Complies with IEC 60270 standards and remains PD- free up to the maximum test voltage for reliable diagnostics.
  • Portable and Practical: Compact design (weighing just 11 kg) allows for easy transport and use in various testing environments.
  • Enhanced Diagnostics: Operates seamlessly with MPD 600 for comprehensive and precise testing outcomes.
  • Cost and Time Efficiency: Detects faults early, preventing costly damage and reducing downtime in operations.
Same category

Other cable & partial discharge testing options

b2 Electronics PDTD 68 Partial Discharge Diagnostics System
Cable & Partial Discharge Testingfrom$780/day
b2 Electronics

PDTD 68

The PDTD68 Partial Discharge Diagnostics System, when paired with the b2 HVA60, enables unmatched insights into insulation degradation…

Read more
Omicron MPD 800 / RBP1 Partial Discharge Measurement System
Cable & Partial Discharge Testingfrom$695/day
Omicron

MPD 800 / RBP1

Our OMICRON MPD 800 universal partial discharge (PD) measurement and analysis system represents the next generation of our widely used and…

Read more
b2 Electronics HVA 68-2 VLF High Voltage Test Set
Cable & Partial Discharge Testingfrom$620/day
b2 Electronics

HVA 68-2

The HVA68-2 is a member of the HVA series with extra power, with an output current up to 88 mA. This extends greatly the maximum load and…

Read more
Back to the catalogue